11.1V Lipo Battery Battery,Rechargeable Battery With Charger,11.1V 8Ah Lithium Battery,Rechargeable Battery Charger,Power Battery Packs Langrui Energy (Shenzhen) Co.,Ltd , https://www.langruibattery.com Fault phenomenon Possible Causes Method of exclusion No heating (the indicator light is off) 1, the power is not connected
2, the fuse burned out
3, the circuit board is bad 1. Check if the heating switch is in the "on" position. Is there a power outlet?
2, replace the fuse
3, replace the circuit board No heating (indicator is on) 1, the heating tube burned out
2, the temperature controller is bad 1, replace the heating tube
2, replace the thermostat Faucet does not produce water 1, the barrel is waterless
2, the water in the smart column inlet is blocked by the big cap 1. Change a bucket of new water
2, remove the waste paper, tear off the back cover on the bottle cap, and then install the large bucket of water No refrigeration (compressor refrigeration) Fluorine leakage Fluorine Leaking water 1, the barrel leaks
2, the faucet leaks
3, inner tube fracture 1, replace the new barrel
2, replace the new tap
3, replace the new inner tube Heating is noisy Slight scaling of the heating tube after long-term use Descaling Not disinfected for half a year Long-term use without disinfection Cleaning and disinfection Leakage Heat pipe leakage Replace the new heating tube Uncooled (electronic cooling) 1, the fan is bad 2, the cooling film is broken
3, the board is broken 1, change the fan
2, change the cooling film
3, change the board