Leakage protection is a safety mechanism designed to automatically cut off the power supply when the leakage current exceeds 30mA within 100 milliseconds. This requires highly sensitive and reliable current detection, along with a stable and dependable relay system. In daily use, various issues may arise, which can lead to the leakage protector not functioning properly. Today, we’ll discuss the common causes and solutions for this problem. ![Leakage Protector Can Not Be Pushed Up](http://i.bosscdn.com/blog/24/74/21/5-1G101142ZW46.png) **Common Reasons Why the Leakage Protector Won’t Reset:** 1. A fault in the connected load, such as a short circuit or insulation damage. 2. The “Reset” button on the panel hasn’t been pressed after a trip. 3. Internal faults in the leakage protector itself, such as mechanical failure or electronic circuit breakdown. **Solutions to Fix the Problem:** First, try disconnecting the load from the leakage circuit breaker. If it can be reset successfully, the issue likely lies in the wiring or connected devices. You should then inspect the wiring and fix any problems before reusing the device. If the circuit breaker still doesn’t reset, it might be damaged and needs to be replaced. In cases where an overload has caused the trip, the circuit breaker may become very hot. At this point, it’s important to wait until it cools down before attempting to reset it. If frequent overloads occur, consider replacing it with a slightly larger-rated circuit breaker. **Important Tips for Using a Leakage Protection Switch:** 1. After installation, maintain a log of operations and establish a proper management system. 2. Regularly test the leakage protection switch by pressing the test button once or twice a month, especially during thunderstorm seasons. 3. Periodically review the performance of the switch and replace it if any faults are detected. 4. Only trained professionals should handle maintenance or repairs. Never attempt to fix it yourself unless you’re qualified. 5. After a storm or unexpected trip, check the system thoroughly to identify the cause. 6. If the cause of a trip isn’t found after inspection, you may attempt to reset it once. If it trips again, investigate further and avoid forced re-energization unless the switch is confirmed faulty. 7. Before reactivating a leakage protector after a trip, perform the necessary action characteristic tests. 8. Always follow the manufacturer’s instructions for setting and using the device. 9. After an electric shock incident within the protected area, check the device and analyze why it didn’t activate. Do not remove the protector until the investigation is complete. 10. Conduct periodic tests to ensure the leakage protector continues to function correctly over time. By following these guidelines, you can ensure the safe and effective operation of your leakage protection system.

Digital Signage Indoor

digital menu screens, digital menu boards, digital signs for businesses, indoor digital signage

Guangdong Elieken Electronic Technology Co.,Ltd. , https://www.elieken.com