The design of the family fire alarm system shall follow the national standard “Design of an Automatic Fire Alarm System for Residential Buildings” and consist of a home fire alarm controller, a home fire detector and a fire alarm.

1. Fire detector settings

Fire detectors generally use flammable gas sensors and smoke sensors. At least one fire detector shall be installed in each bedroom and living room. When combustible gas detectors are set in the kitchen, the following requirements shall be met.

1) Users who use natural gas should select methane detectors. Users who use liquefied gas should select propane detectors. Users who use coal gas should choose carbon monoxide detectors.

2) When the hoses and connectors for connecting gas cookers are inside the cabinet, the detectors should be set inside the cabinets.

3) The methane detector should be set in the top kitchen, and the naphtha should be set in the lower part of the kitchen. Carbon monoxide detectors can be located in the lower part of the kitchen or in other locations.

4) combustible gas detector should not be set directly above the cooker.

5) It is recommended to use combustible gas detectors that have a linkage function and can automatically turn off the gas.

6) The gas shut-off valve of the detector linkage should be a shut-off valve that the user can reset itself and should have the function of automatic protection of the hose fall off.

Three minutes let you read intelligent home interior fire protection design

2 home fire alarm controller settings

Home fire alarm controllers should be set independently in each house, and should be set in the obvious and easy to operate parts, when using wall-mounted installation, the bottom margin height should be 1.3 ~ 1.5m.

The home fire alarm controller with video intercom function should be set near the entrance door.

3. Fire alarm settings

Fire alarms located in public areas of residential buildings should have voice capabilities. And it should be able to accept the linkage control or be controlled directly by the manual fire alarm button signal.

The floor of each alarm should not exceed 3 floors, and an automatic fire alarm or manual fire alarm button should be set in the obvious location on the first floor.

Related browsing:

Article: How unicor smart glass locks

Recommended: smart lock ten brand-name fingerprint lock joining agent smart door lock management software

Benchtop DC Power Supplies

SMP series Bench DC Power Supplies are economical, MOSFETs-based, high switching speed, high power density desktop DC power supplies with output power covering 300W ~ 6KW, and maximum voltage up to 800VDC.

Compared with IGBT-based DC switching power supplies, MOSFET-based switching power supplies have a higher switching frequency, making this series Benchtop DC power supplies can use smaller semiconductor devices and LC filter units while ensuring low ripple, high precision, and fast response characteristics of the Benchtop Laboratory Power Supplies DC output. Which gives more space to use a smaller chassis size at the same output power, resulting the high-power density feature of this series Benchtop AC DC power supplies.

Smp3000 Benchtop Dc Power Supply Front ViewSmp3000 Bench Switching Dc Power Supply Rear View
The main design purpose of this series of Bench AC-DC power supplies is to fulfill the needs of small laboratory test, precise experiment and universities.

At present, this series of Bench AC DC power supplies below 1KW adopts desktop chassis to match laboratory applications, they are mainly used in LED testing, small electroplating, heating of new materials, electrical component testing and other applications.

Bench DC Power Supplies, Desktop DC Power Supplies, Bench Laboratory Power Supplies, Benchtop AC DC Power Supplies, Bench AC-DC Supplies

Yangzhou IdealTek Electronics Co., Ltd. , https://www.idealtekpower.com