Do you know the difference of Yoga Laptop and 2 in 1 laptop? No. 1 is yoga notebook with 360 flip rotating absolutely; No.2 is laptop yoga slim is just like normal Education Laptop-connecting screen with keyboard, but 2 in 1 laptop tablet with pen is separately, you can use the monitor part as a window tablet. In one word, every intel yoga laptop have all the features and function of tablet 2 in 1 laptop except separated screen and keyboard. From the cost, windows yoga laptop is much higher than 2 in 1 type., cause usually former with more complicated craft and quality.
What other products you mainly produce? It`s education laptop, Gaming Laptop, engineering laptop, Android Tablet, Mini PC and All In One PC. You can see more than 5 different designs on each series, believe always have right one meet your special application or your clients demands. Therefore, what you need to do is just to get all the requirement details from your clients, then share the complete information with us, then we can provide the most suitable situation.
Of course, you can also call or email or send inquiry of what you need, thus can get value information much quickly.
2 In 1 Laptop,2 In 1 Laptop Sale,2 In 1 Laptop Tablet With Pen,Tablet 2 In 1 Laptop,2 In 1 Laptop Deals Henan Shuyi Electronics Co., Ltd. , https://www.shuyiaiopc.com
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specifications:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
 No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
6.0
2.5
0.1
1.2
0.2
1.9
37.9
1.87
2.32
3 X 35
6.9
2.5
0.1
1.3
0.5
2.0
41.5
2.10
2.73
3 X50
8.2
2.5
0.1
1.3
0.5
2.0
44.3
2.37
3.22
3 X 70
9.7
2.5
0.1
1.4
0.5
2.1
47.9
2.77
4.00
3 X 95
11.3
2.5
0.1
1.4
0.5
2.2
51.6
3.21
4.91
3 X 120
12.8
2.5
0.1
1.5
0.5
2.4
55.4
3.69
5.84
3 X 150
14.2
2.5
0.1
1.5
0.5
2.5
58.6
4.15
6.85
3 X 185
15.9
2.5
0.1
1.5
0.5
2.6
62.5
4.73
8.11
3 X 240
18.3
2.6
0.1
1.6
0.5
2.7
68.5
5.62
10.05
3 X 300
20.4
2.8
0.1
1.7
0.5
2.9
74.5
6.55
12.11
3 X 400
23.2
3.0
0.1
1.9
0.8
3.2
83.6
8.78
15.86
3 X 500
26.4
3.2
0.1
2.1
0.8
3.4
93.0
10.52
18.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
6.0
3.4
0.1
1.3
0.5
2.0
43.4
2.16
2.61
3 X 35
6.9
3.4
0.1
1.3
0.5
2.0
45.4
2.36
2.99
3 X50
8.2
3.4
0.1
1.4
0.5
2.2
48.8
2.69
3.54
3 X 70
9.7
3.4
0.1
1.5
0.5
2.3
52.4
3.10
4.33
3 X 95
11.3
3.4
0.1
1.5
0.5
2.4
56.1
3.56
5.26
3 X 120
12.8
3.4
0.1
1.5
0.5
2.5
59.5
4.04
6.19
3 X 150
14.2
3.4
0.1
1.5
0.5
2.6
62.7
4.49
7.19
3 X 185
15.9
3.4
0.1
1.6
0.5
2.6
66.6
5.12
8.49
3 X 240
18.3
3.4
0.1
1.7
0.5
2.8
72.4
5.99
10.42
3 X 300
20.4
3.4
0.1
1.8
0.5
3.0
77.5
6.86
12.42
3 X 400
23.2
3.4
0.1
1.9
0.8
3.2
85.4
8.97
16.05
3 X 500
26.4
3.4
0.1
2.0
0.8
3.4
93.7
10.65
19.50
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
6.0
4.5
0.1
1.4
0.5
2.1
48.6
2.53
2.98
3 X 35
6.9
4.5
0.1
1.4
0.5
2.2
50.7
2.76
3.39
3 X50
8.2
4.5
0.1
1.5
0.5
2.3
53.9
3.10
3.95
3 X 70
9.7
4.5
0.1
1.5
0.5
2.4
57.4
3.51
4.74
3 X 95
11.3
4.5
0.1
1.5
0.5
2.6
61.2
4.05
5.75
3 X 120
12.8
4.5
0.1
1.6
0.5
2.6
64.7
4.56
6.72
3 X 150
14.2
4.5
0.1
1.6
0.5
2.7
67.9
5.04
7.74
3 X 185
15.9
4.5
0.1
1.7
0.5
2.8
71.9
5.66
9.04
3 X 240
18.3
4.5
0.1
1.8
0.5
3.0
77.7
6.56
11.00
3 X 300
20.4
4.5
0.1
1.9
0.8
3.2
84.1
8.39
13.96
3 X 400
23.2
4.5
0.1
2.0
0.8
3.3
90.5
9.71
16.79
3 X 500
26.4
4.5
0.1
2.1
0.8
3.5
98.8
11.45
20.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
Â
Â
Â
Â
Â
Â
Â
Â
Â
3 X 35
6.9
5.5
0.1
1.5
0.5
2.4
55.6
3.14
3.77
3 X50
8.2
5.5
0.1
1.5
0.5
2.5
58.6
3.49
4.34
3 X 70
9.7
5.5
0.1
1.5
0.5
2.6
62.1
3.93
5.16
3 X 95
11.3
5.5
0.1
1.6
0.5
2.6
65.7
4.46
6.16
3 X 120
12.8
5.5
0.1
1.7
0.5
2.7
69.4
5.00
7.15
3 X 150
14.2
5.5
0.1
1.7
0.5
2.8
72.6
5.49
8.19
3 X 185
15.9
5.5
0.1
1.8
0.5
3.0
76.9
6.16
9.53
3 X 240
18.3
5.5
0.1
1.9
0.8
3.2
83.9
7.87
12.31
3 X 300
20.4
5.5
0.1
2.0
0.8
3.2
88.6
8.96
14.52
3 X 400
23.2
5.5
0.1
2.1
0.8
3.5
95.4
10.35
17.43
3 X 500
26.4
5.5
0.1
2.2
0.8
3.7
103.7
12.45
20.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
Â
Â
Â
Â
Â
Â
Â
Â
Â
3 X 35
Â
Â
Â
Â
Â
Â
Â
Â
Â
3 X50
8.2
8.0
0.1
1.7
0.5
2.8
70.4
4.56
5.41
3 X 70
9.7
8.0
0.1
1.7
0.5
2.9
73.9
5.04
6.26
3 X 95
11.3
8.0
0.1
1.8
0.5
3.0
77.7
5.62
7.32
3 X 120
12.8
8.0
0.1
1.9
0.8
3.2
82.8
6.99
9.15
3 X 150
14.2
8.0
0.1
1.9
0.8
3.2
85.8
7.56
10.26
3 X 185
15.9
8.0
0.1
2.0
0.8
3.3
89.9
8.30
11.67
3 X 240
18.3
8.0
0.1
2.1
0.8
3.5
95.7
9.36
13.79
3 X 300
20.4
8.0
0.1
2.2
0.8
3.6
100.6
10.51
16.07
3 X 400
23.2
8.0
0.1
2.3
0.8
3.8
107.2
11.99
19.07
3 X 500
26.4
8.0
0.1
2.4
0.8
4.0
120.1
14.15
23.85
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specifications:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
 No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
6.0
2.5
0.1
1.2
0.2
1.9
37.9
1.87
2.32
3 X 35
6.9
2.5
0.1
1.3
0.5
2.0
41.5
2.10
2.73
3 X50
8.2
2.5
0.1
1.3
0.5
2.0
44.3
2.37
3.22
3 X 70
9.7
2.5
0.1
1.4
0.5
2.1
47.9
2.77
4.00
3 X 95
11.3
2.5
0.1
1.4
0.5
2.2
51.6
3.21
4.91
3 X 120
12.8
2.5
0.1
1.5
0.5
2.4
55.4
3.69
5.84
3 X 150
14.2
2.5
0.1
1.5
0.5
2.5
58.6
4.15
6.85
3 X 185
15.9
2.5
0.1
1.5
0.5
2.6
62.5
4.73
8.11
3 X 240
18.3
2.6
0.1
1.6
0.5
2.7
68.5
5.62
10.05
3 X 300
20.4
2.8
0.1
1.7
0.5
2.9
74.5
6.55
12.11
3 X 400
23.2
3.0
0.1
1.9
0.8
3.2
83.6
8.78
15.86
3 X 500
26.4
3.2
0.1
2.1
0.8
3.4
93.0
10.52
18.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
6.0
3.4
0.1
1.3
0.5
2.0
43.4
2.16
2.61
3 X 35
6.9
3.4
0.1
1.3
0.5
2.0
45.4
2.36
2.99
3 X50
8.2
3.4
0.1
1.4
0.5
2.2
48.8
2.69
3.54
3 X 70
9.7
3.4
0.1
1.5
0.5
2.3
52.4
3.10
4.33
3 X 95
11.3
3.4
0.1
1.5
0.5
2.4
56.1
3.56
5.26
3 X 120
12.8
3.4
0.1
1.5
0.5
2.5
59.5
4.04
6.19
3 X 150
14.2
3.4
0.1
1.5
0.5
2.6
62.7
4.49
7.19
3 X 185
15.9
3.4
0.1
1.6
0.5
2.6
66.6
5.12
8.49
3 X 240
18.3
3.4
0.1
1.7
0.5
2.8
72.4
5.99
10.42
3 X 300
20.4
3.4
0.1
1.8
0.5
3.0
77.5
6.86
12.42
3 X 400
23.2
3.4
0.1
1.9
0.8
3.2
85.4
8.97
16.05
3 X 500
26.4
3.4
0.1
2.0
0.8
3.4
93.7
10.65
19.50
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
6.0
4.5
0.1
1.4
0.5
2.1
48.6
2.53
2.98
3 X 35
6.9
4.5
0.1
1.4
0.5
2.2
50.7
2.76
3.39
3 X50
8.2
4.5
0.1
1.5
0.5
2.3
53.9
3.10
3.95
3 X 70
9.7
4.5
0.1
1.5
0.5
2.4
57.4
3.51
4.74
3 X 95
11.3
4.5
0.1
1.5
0.5
2.6
61.2
4.05
5.75
3 X 120
12.8
4.5
0.1
1.6
0.5
2.6
64.7
4.56
6.72
3 X 150
14.2
4.5
0.1
1.6
0.5
2.7
67.9
5.04
7.74
3 X 185
15.9
4.5
0.1
1.7
0.5
2.8
71.9
5.66
9.04
3 X 240
18.3
4.5
0.1
1.8
0.5
3.0
77.7
6.56
11.00
3 X 300
20.4
4.5
0.1
1.9
0.8
3.2
84.1
8.39
13.96
3 X 400
23.2
4.5
0.1
2.0
0.8
3.3
90.5
9.71
16.79
3 X 500
26.4
4.5
0.1
2.1
0.8
3.5
98.8
11.45
20.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
Â
Â
Â
Â
Â
Â
Â
Â
Â
3 X 35
6.9
5.5
0.1
1.5
0.5
2.4
55.6
3.14
3.77
3 X50
8.2
5.5
0.1
1.5
0.5
2.5
58.6
3.49
4.34
3 X 70
9.7
5.5
0.1
1.5
0.5
2.6
62.1
3.93
5.16
3 X 95
11.3
5.5
0.1
1.6
0.5
2.6
65.7
4.46
6.16
3 X 120
12.8
5.5
0.1
1.7
0.5
2.7
69.4
5.00
7.15
3 X 150
14.2
5.5
0.1
1.7
0.5
2.8
72.6
5.49
8.19
3 X 185
15.9
5.5
0.1
1.8
0.5
3.0
76.9
6.16
9.53
3 X 240
18.3
5.5
0.1
1.9
0.8
3.2
83.9
7.87
12.31
3 X 300
20.4
5.5
0.1
2.0
0.8
3.2
88.6
8.96
14.52
3 X 400
23.2
5.5
0.1
2.1
0.8
3.5
95.4
10.35
17.43
3 X 500
26.4
5.5
0.1
2.2
0.8
3.7
103.7
12.45
20.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor
Nominal Diameter of Conductor
Nominal Thickness of Insulation
Nominal Thickness of Copper Tape Screen
Nominal Thickness of Inner Sheath
Nominal Thickness of Steel Tape Armouring
Nominal Thickness of PVC Sheath
Approx. Overall Diameter
Approx. Weight
Al Conductor
Cu Conductor
No. X mm2
mm
mm
mm
mm
mm
mm
mm
kg/m
kg/m
3 X 25
Â
Â
Â
Â
Â
Â
Â
Â
Â
3 X 35
Â
Â
Â
Â
Â
Â
Â
Â
Â
3 X50
8.2
8.0
0.1
1.7
0.5
2.8
70.4
4.56
5.41
3 X 70
9.7
8.0
0.1
1.7
0.5
2.9
73.9
5.04
6.26
3 X 95
11.3
8.0
0.1
1.8
0.5
3.0
77.7
5.62
7.32
3 X 120
12.8
8.0
0.1
1.9
0.8
3.2
82.8
6.99
9.15
3 X 150
14.2
8.0
0.1
1.9
0.8
3.2
85.8
7.56
10.26
3 X 185
15.9
8.0
0.1
2.0
0.8
3.3
89.9
8.30
11.67
3 X 240
18.3
8.0
0.1
2.1
0.8
3.5
95.7
9.36
13.79
3 X 300
20.4
8.0
0.1
2.2
0.8
3.6
100.6
10.51
16.07
3 X 400
23.2
8.0
0.1
2.3
0.8
3.8
107.2
11.99
19.07
3 X 500
26.4
8.0
0.1
2.4
0.8
4.0
120.1
14.15
23.85
Model NO.: YJV/YJV22/YJV32
Standards: IEC60502 or Others
Capacity: 2000km/Month
Delivery Length: Accord with The Request
Min.Order Qty: 1km
Trademark: Jiapu
Transport Package: Wooden Drum, Iron Wooden Drum, Iron Drum
Specification: IEC, ASTM, DIN, BS, GB, Any standard
Origin: Henan China
HS Code: 4101962331
Model NO.: YJV/YJV22/YJV32
Standards: IEC60502 or Others
Capacity: 2000km/Month
Delivery Length: Accord with The Request
Min.Order Qty: 1km
Trademark: Jiapu
Transport Package: Wooden Drum, Iron Wooden Drum, Iron Drum
Specification: IEC, ASTM, DIN, BS, GB, Any standard
Origin: Henan China
HS Code: 4101962331
8.7/10kV Copper Conductor XLPE Power Cable